FLUKE 1625-2 KIT PDF

Fluke FLUKE KIT Earth Ground Tester: : Industrial & Scientific. Buy Fluke Earth & Ground Resistance Tester Kit, For Use With Series FLUKE KIT. Browse our latest earth-ground-resistance-tester-kits offers. The complete model kit comes with the or tester, test leads, 4 earth ground stakes, 3 cable reels with wire,. 2 clamps, batteries, and manual—.

Author: Virisar Yozshuramar
Country: Solomon Islands
Language: English (Spanish)
Genre: Environment
Published (Last): 11 September 2005
Pages: 278
PDF File Size: 16.77 Mb
ePub File Size: 9.70 Mb
ISBN: 843-5-55143-626-7
Downloads: 4224
Price: Free* [*Free Regsitration Required]
Uploader: Tygogar

Automatic check if error is kept within the limits required by IEC You can also perform earth ground tests in places you have not considered before: Rest of Europe English. You can change your cookie settings by reading our cookie policy. Automatic Frequency Control to identify existing interference and choose a measurement frequency to minimize its effect, thus providing a more accurate earth ground value.

This test method only works if a bonded earth ground system exists for the building or structure under test, but most are. Typical 8 seconds with a fixed frequency 162-52 sec. Then the tester automatically determines kti resistance of the earth ground rod. Fluke Earth Ground Tester offers fast, accurate earth ground testing using all four kir methods. Gone are the days of spending time placing and connecting stakes for each earth ground rod on your system — a major time saver.

Typical 8 seconds with a fixed frequency 30 sec.

Fluke GEO Earth Ground Tester Kit | Fluke

The Fluke 6125-2 earth ground testers are able to measure earth ground loop resistances using only clamps. Velg ditt lands side. The Fluke offers you simpler, faster earth ground tests than ever before.

Tool bag One 2. Then the tester automatically determines the resistance of the earth ground rod. Fluke FC Electrical Tester. You’ll still have a chance to review your order. Current and voltage measurement with probe as per EN and current measurement in the individual branch with additional current transformer patent applied for. The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.

  DUPLO BLUME ANLEITUNG PDF

Rest of Europe English.

Fluke 1625 Earth & Ground Resistance Tester Kit, For Use With 1625 Series

No earth ground stakes are used at all. With Stakeless testing, the earth ground rod does not need to be disconnected — leaving the bonded earth ground system intact during test. No earth ground stakes are used at all. Key features Stakeless Testing The Fluke earth ground tester is able to measure earth ground loop resistances using only clamps. The Most Complete Tester The Fluke is a unique earth ground tester that can performs all four types of earth ground measurement: This kit provides all the necessary equipment to With this test method, two clamps are placed around the earth ground rod and each are connected to the tester.

RS Components Statement of conformity. This earth ground tester also gives you world-class accessories that take the tedium out of earth ground testing.

Skip to main content. Overview The Fluke and earth ground testers are able to measure earth ground loop resistances using only clamps. Minimal current in single branch to be measured 0. Stakeless measurement of resistance in closed loops using two current transformers. You will hear from us soon!

And you can store up to records and access them easily via the USB port. The Fluke improves your earth ground testing process with: HTTP status code of was returned.

Minimal current in single 16255-2 to be measured 0. With 4-pole measurement wires on H, S, ES can be extended without additional error.

  PRUEBA TERMAN MERRIL PDF

Our website uses cookies and similar technologies to provide you with a better service while searching or placing an order, for analytical purposes and to personalise our advertising to you.

Offering a simple error-free connection with colour coded cables to match connecting terminals.

Stakeless measurement of resistance in closed loops using two current transformers. With Stakeless testing, the earth ground rod does 125-2 need to be disconnected – leaving the bonded earth ground system intact during test. This test method only works if a bonded earth ground system exists for the building or structure under test, but most are.

The product detailed below complies with the specifications published by RS Components. The large rotary switch and buttons are easy to operate even with a gloved hand. They ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC and all relevant local standards. This technique eliminates the dangerous, and time consuming job of disconnecting parallel grounds, and finding suitable locations for auxiliary ground stakes. A known, fixed voltage is induced by one clamp and the current is measured using the second clamp.

Automatic check if error is kept within the limits required by IEC No earth ground stakes are used at all. The Fluke offers data storage and download capabilities via USB port.

The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified. Product overview Specifications Models Resources Accessories. Rest of Europe English. The is also very easy to use.